The Vulcan Hart 412788-60 Thermocouple H/D 72 inch 20-30mV is a temperature sensor that is designed to detect the presence of flames and also assist in safe gas use in a heating system. This component works by producing a millivolt signal when hot, and this signal is utilized to control the flow of gas during the ignition and further operation. In practical service conditions, it is applied in the installation or maintenance where precise flame detection is needed to make the system operate properly. The long 72-inch lead allows for the flexibility in positioning of equipment layouts.

Dimensions

  • Length: 7.62 cm
  • Width: 6.35 cm
  • Height: 2.54 cm
  • Weight: 0.181 kg
https://partsfe.com/media/catalog/product/v/u/vulcan-hart-412788-60-thermocouple-h-d-72-20-30-mv-61515-2.jpg

Product Notes

  • Heavy-Duty 72" Thermocouple, 20-30 Milevolt.
  • Coaxial Thermocouple Threads = 11/32"-32
BAKERS PRIDE:
AS-M1296A, BKPM1296A, BKPM1296X, M1296A, M1296X
COOKING PERFROMANCE GROUP:
351302170058
HOBART:
00-428305-00001, 428305-00001, 428305-1, HOB00-428305-00001, HOB428305-00001, HOB428305-1
Write Your Own Review
You're reviewing:Vulcan Hart 412788-60 Thermocouple 72" Long 20-30mV
Your Rating
Customer Questions
No Questions

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off the gas supply and unplug the appliance.

Step2: Remove the old thermocouple from the pilot assembly.

Step3: Inspect the pilot bracket and gas fittings for wear or damage.

Step4: Insert the new thermocouple into the pilot flame bracket.

Step5: Secure with the mounting screw provided.

Step6: Attach the thermocouple nut to the gas valve inlet.

Step7: Turn on the gas and test the pilot flame to ensure proper detection.

Step8: Verify the thermocouple shuts off the gas when the flame is extinguished.