Garland CKG0893-01 Thermostat Type-K 100°F-450°F

Special Price £102.33 Regular Price £216.81
In stock
SKU
CKG0893-01
Manufacturer:
The Garland CKG0893-01 Thermostat K with a 1/4 in x 7 in sensing element and 0.187 in D-stem is a temperature control unit that is calibrated between 100°F and 450°F and is utilised in commercial cooking equipment, and appliance to monitor and control the internal temperature. It detects heat through the stem, and feeds the appliance control system so that it can make changes to the heating components or gas valves to keep the desired temperature. It is installed in the oven cavity or control housing in kitchens and foodservice conduction and provides proper temperature regulation during cooking.

Dimensions

  • Length: 20.32 cm
  • Width: 5.08 cm
  • Height: 6.35 cm
  • Weight: 0.231 kg
https://partsfe.com/media/catalog/product/g/a/garland-ckg0893-01-k-type-thermostat-w-1-4-x-7-nickel-bulb-187-d-stem-black-knob-60580-2.jpg

Product Notes

  • T'Stat Type- K Temp 100-450
  • Bulb 1/4" X 7" Nickel Cap 36"
  • Vert Mount 1 .187" D-Stem Flat Down
  • Dial To Use # 221395 Black Knob W/O Insert
  • Insert To Use # 221261 Off-450-100
  • Garland Grill E24, Series: 680 Electric
U-LINE:
5300-204, K617-24
Write Your Own Review
You're reviewing:Garland CKG0893-01 Thermostat Type-K 100°F-450°F
Your Rating
Customer Questions
No Questions

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off the unit before beginning the installation process.

Step2: Open the control panel carefully to locate the thermostat and its capillary tube.

Step3: Disconnect all wiring connections and gently remove the sensing bulb from its position.

Step4: Remove the old thermostat from its mounting bracket.

Step5: Install the new thermostat securely in the same location.

Step6: Reconnect wiring and properly route the sensing bulb.

Step7: Close the panel and restore power to the unit.