Garland 1019418 Range Thermocouple 18" Long 20-30mV 1980 Series

SKU: 1019418 3-1019418 Brand: Availability:
Out of Stock
(0)

£15.23 Price reduced from £27.20
Save £11.97


Have a Question? +44 2921680023

Specifications:

  • 1980 Series Snap Fit 18" Thermocouple, 20-30 Mv
  • American Permanent Ware Griddle Ggm, Ggt
  • Comstock Castle Oven Bake, Barbeque & Pizza Ovens.
  • Series: C, D, F, K.
  • Dynamic Cooking Systems Oven All
  • Garland Broiler 6-40/50S, 7-40/50S, 8-40/50S, 60-40/50R
  • Oven Series: H281, P280. Standard Oven From 03/99 In
  • Canada Only, Range: G20-Sph
  • Imperial Model?
  • Star Fryer M14, Mi4 (D,Dl), M18, Mi8(D,Dl), M43, 215B, 216,
  • 403 404
  • Us Range Oven P-4-20.
  • Wolf Oven Ch, Chssd, R

Description

The Garland 1019418 Thermocouple 18" Long 20-30mV 1980 Series is a sensing element that is intended to be used in commercial gas ranges, where the flame of the burner is monitored to aid in the better flow of gas. It is applied in professional kitchens and restaurants as well as in catering settings where consistent ignition and flame detection are needed on an ongoing cooking process. It is connected to gas control system of the appliance, and it is used with the other components, as it senses the presence of heat in the pilot flame.

Dimensions:

  • Weight: 0.05 kgs
  • Length: 12.7 cm
  • Height: 1.27 cm
  • Width: 10.16 cm

AMERICAN RANGE:

10485 A11100 AMRA11100

ANETS:

ANEP8900-32 P8900-32

APW WYOTT:

1473103 AS-1473103

CECILWARE:

F002A F002F GMF002A GMF002F

COMSTOCK CASTLE:

17005 COM17005 COMT46 T46

DYNAMIC COOKING SYSTEMS:

13007 13007-01

IMPERIAL:

1121 30030 IMP1121

ROYAL RANGE:

2175 2179

STAR MFG:

2J-6726 2J6726 6726 H456

STERO:

STA2J-6726 STA2J6726 STA6726 STAH456

TRI-STAR:

310210 TRS310210

U-LINE:

1980-018

Step1: Turn off the gas supply and allow the appliance to cool.

Step2: Remove the old thermocouple from the pilot assembly.

Step3: Inspect the pilot bracket and gas fittings for corrosion.

Step4: Insert the new thermocouple into the pilot flame bracket.

Step5: Secure it in place using the mounting screw.

Step6: Reconnect the thermocouple nut to the gas valve.

Step7: Turn on the gas and test the pilot flame.

Step8: Ensure the thermocouple properly shuts off gas when the flame is extinguished.